Installation Guide

THIS UNIT MUST BE FITTED WHERE ANY WATER SPILLAGE WILL NOT CAUSE DAMAGE
NB -ONLY ONE INLET CAN BE DRILLED INTO THE CABINET. IF CONNECTING TO 2 OVENS THE OUTLETS FROM THEM MUST MERGE PRIOR TO THE COMBI PUMP INLET
Consideration should be made when positioning the CombiPump to allow for access for servicing and maintenance.

1.Position the CombiPump in the required area and using the diagram below or the supplied template. Decide where the inlet position will be made.

2.Drill the desired inlet hole into the holding tank dependant on the model and fit the deflector supplied. NB See information below for minimum inlet heights

3. Inlet MUST NOT be drilled in hatched areas or anywhere on Side D. This will damage the pump and void any warranty and result in breakdown of the unit.

Minimum Inlet heights

CombiPump CB4
The height of the inlet on the Combi 4 should be drilled no lower than 70mm centre line.

The 70mm should be measured from the bottom of the cabinet upwards.

Pump activation 40mm

CombiPump CB7
The height of the inlet on the Combi 7 should be drilled no lower than 190mm centre line.

The 190mm should be measured from the bottom of the cabinet upwards.

Pump activation 75mm

Hatched areas indicate where inlet connections are NOT permitted
Dimensions & Connections

Dimensions: Height 470mm, Width 250mm, Depth 450mm.
Inlet 1.5 “ with supplied Deflector Outlet 3/4 “ BSP to 15mm or 22mm pipe.
Airgap required at top of run.
Run must be vertical with no bends.
Outlet pipe size: 15mm
Head: 9 metre
Capacity: 160 litres/per minute

Specifications
PUMP
Pump Duty                                Continuously rated
Maximum temperature          96° C
Operating temperature          85° C
ELECTRICAL
Phase                                         Single 239 Volts 50Hz
Current                                      2.45 Amps FLC
Motor output                            0.4kW
Pump speed                              2800 RPM
FLOW & PRESSURE
Maximum input flow               80 litres per minute
Output flows                             160 litres per minute @ 9m head
BMS high water                        Available on request
CONTROL
Method                                      Float switch
CABINET
Outer casing                              M.D.P.E
Capacity                                     15 litres
Dimensions CB4 & CB7           H:445mm W:260mm D:420mm
Inlet water connection            1 ½” connection (fittings supplied)
Outlet water connection         3/4” BSP PVC
Pumping Capacities
Having an operational ability to pump away to a 9 metre head at up to 160 litres per minute and to withstand water temperatures up to 96 degrees centigrade together with a choice of capacities to suit any size oven means the CombiPump series is the ideal alternative to expensive alterations of existing drainage systems.
*Figures are approximate and for indication only, volumes may vary dependant on water temperature and contaminants.

 

This unit is a waste water pump specifically designed for combination oven units, it is not a food disposal unit or macerator.

Regular cleaning may be required, please test the water temperature before inserting hands into the unit.

Outlet pipe size minimum 15mm

Maximum straight up head is 9 Metres

Maximum pipe run is 10 metres and should include an air gap or Tundish.

Restriction from waste or sediment accumulated in the pipework could affect the pump operation and is not covered by the warranty on the unit.

In the event of the pump failing to operate when fitted to long runs of pipework on the outlet, the pump can be tested easily by disconnection of the outlet and connection of a short piece of hose into a bucket to discount outlet pipework issues.

Call today on 01279 780250

WaterCare
Regal House
South Road
Harlow
CM20 2BL
Tel: 01279 780250
orders@watercare.co.uk
enquiries@watercare.co.uk
www.watercare.co.uk